The Phase II PTG-3500 series of gauges can perform two different methods of calculating thickness measurement by utilizing the characteristics of both eddy current and magnetic induction. Testing performance is both non-destructive and extremely accurate. With these state of the art thickness gauges, you can easily detect the thickness of nonmagnetic coating on a magnetic substrate (ferrous) or an insulating coating on a non-magnetic conductive substrate (non-ferrous) utilizing either an integrated probe or our version that comes with an external probe.The?PTG-3550 can be used in many areas of industry including manufacturing, general engineering, commercial inspection, etc.

The PTG-3550 comes complete with 1pc external auto-detect Ferrous/Non-Ferrous probe, 2 substrate samples(steel, aluminum), 4 calibrated thickness specimens, carry case, batteries and operation manual.

Main Technical Data:

Measuring range: 0-2000 mm max. or 0-80 mils

Resolution: 0.1mm/0.01mils(0-99m m) or 1m m (over 100mm)

Guaranteed tolerance: After one-point calibration:? /- 1-3%n or 2mm (whichever is greater)

Display: 4 digits (digit height = 10mm/0.4)

Min. measuring area: 0.2 x 0.2 (5mm x 5mm)

Min. radius of curvature: Convex: 0.12 (3mm) Concave: 1.2? (30mm)

Min. substrate thickness: Ferrous: 20 mils (0.5mm) Non-ferrous: 2 mils (50 mm)

Calibration: Zero Calibration/Foil calibration

Max. Surface temperature of test object: 302 degrees F (contact time max is 2 seconds)

Power source: 4-AAA batteries

Dimensions: 161 x 69 x 32mm

Weight: 9oz. (260g)

Gauge

Integrated Coating Thickness Gauge with External Probe

Reviews

There are no reviews yet.

Be the first to review “Integrated Coating Thickness Gauge with External Probe”

Your email address will not be published. Required fields are marked