Measures the ferrite content in austenitic and duplex steel according to the magnetic induction method. Comes with either low, middle or high standards. High being the most common in the U.S. Choose when ordering.

U.S. Sales ONLY!! No Exports!

Now comes?with the new color display and FREE DataCenter Software and Interface Cable!

The FERITSCOPE? measures the ferrite content in austenitic and duplex steel according to the magnetic induction method. All magnetizable structure sections are measured i.e, in addition to delta ferrite also strain-induced martensite, for example, or other ferritic phases. The instrument is suitable for measurements according to the Basler Standard or according to DIN 32514-1. Areas of application are on-site measurements, e.g.,of austenitic platings as well as weld seams in stainless steel pipes, containers, boilers or other products made of austenitic or duplex steel.

Duplex steel is used increasingly in the chemical?and petrochemical industries, e. g., for boilers and?pipelines. A ferrite deficit in the weld seam area leads?to strength reduction, an excess ferrite content to a?reduction in toughness and ductility.

In particular when welding duplex steel, the ferrite?content in the welding area can easily assume unfavorable values either due to unsuitable welding filler?materials or through poor heat input or heat removal.?Only an onsite measurement can provide the assurance that the processing did not change the optimum ferrite content in an unfavorable manner at?the expense of mechanical or corrosion-resistance?properties.

Characteristic features:

  • Non-destructive measurement of the ferrite content in a range of 0.1 to 110 FN or 0.1 to 80% Fe in austenitic and duplex steel
  • User-friendly instrument operation
  • Robust Housing
  • Large display rich in contrast with 240×160 pixels
  • USB port for data transfer to PC or printer
  • Mechanical sliders to cover keys not required for the measurement operation
  • Ready to make measurements right after power-up
  • Measurement automatic upon probe placement through external trigger via instrument button or PC
  • Automatic probe recognition
  • Audible signal at measurement acquisition
  • Only one calibration required for the entire practically relevant measurement range from 0.1 to about 90 FN. Measurement accuracy according to ANSI/AWS A4.2M/A4.2:1997 standard
  • Calibration with standards traceable to TWI secondary standards or with customer-specific standards
  • Adjustable instrument switch-off for continuous operation
  • Lockable keyboard/restricted operating mode. Audible and visual warning when tolerance limits are exceeded.
  • Free-running display with additional presentation of the reading as an analog bar between the tolerance limits.
  • Matrix measuring mode for connected multi-point measurements, e. g., in a pre-defined surface array
  • Capability of averaging measurement data: Only the mean value of several readings will be stored
  • Measurement acquisition through area measurement
  • Possible: Only single readings until probe lift-off are captured and averaged
  • Capability to measure continuously with the probe placed on the specimen
  • Outlier rejection for the automatic elimination of erroneous measurements
  • Overwriting of erroneous and already stored readings through overwriting
  • Application linking mode: Ability for common normalization/calibration of applications
  • Designations for applications through the optional PC program MP-Name
  • Data transfer to a PC into an Excel spreadsheet with the optional PC program PC-Datex
  • Data transfer to a PC into an Access database with the optional PC program PC-Datacc
  • It can hold up to 20,000 readings and 100 applications for measurement data and application-specific calibrations
  • Separation of the measurement data in up to 4000 blocks which are time and date stamped.
  • Battery and line power operation (AC adapter optional accessory)

Offered for sale in the USA?only.


The Feritscope FMP30 Standard Kit includes:?probe type FGAB1.3FE, Fischer DataCenterSoftware with interface cable, carrying strap, battery set, guidelines, operators manual, USB drivers on CD, interface cable FMP/PC and One set of standards (specify high, medium* or low range, * medium standard set is supplied if no other set is specified).

Note: A combination of Low and High Range Standard sets cover the full range due to overlap. One standard set is included in the instrument price.

LOW RANGE?Ferrite Standard Set – 0.3 – 10% (0.4-9FN)

MID RANGE Ferrite Standard Set – 1.5 – 30% (2-33FN)

HIGH RANGE Ferrite Standard Set – 10.5 – 80% (9-110FN)